Go gauge for caps on finished lamps E12, 7006-27H-1

Include ISO 17025 CNAS & ILAC Test Report
Item No.: 7006-27H-1
Made in China
Product description: Go gauge for caps on finished lamps E12, 7006-27H-1.

go gauge for caps on finished lamps E12, 7006-27H-1


Purpose:

To check the maximum dimensions of the screw thread and dimension T1 minimum of E12 caps on finished lamps.


Testing:

When the cap on a finished lamp has been screwed into the gauge as far as it will go, the centre contact shall be co-planar with, or project beyond surface X. When the lamp is being removed from the gauge, at least two full turns shall be required to disengage the threads.

This gauge shall be used only in conjunction with the gauge specified on sheet 7006-27J.